Accu-Chek Aviva systems offer convenient glucose monitoring, designed for ease of use and effective diabetes management, with readily available user manuals and guides.
These systems, including the Accu-Chek Aviva Connect, provide quantitative glucose measurements from capillary whole blood, aiding in glucose control monitoring for individuals.
What is the Accu-Chek Aviva?
The Accu-Chek Aviva is a blood glucose monitoring system designed to help individuals manage their diabetes effectively. It’s a device used to quantitatively measure the glucose levels in fresh whole blood samples – obtained from fingertips or approved alternative sites. This system utilizes Accu-Chek Aviva test strips for accurate readings, assisting in monitoring the effectiveness of diabetes control plans.
Available resources, like comprehensive user manuals in PDF format, provide detailed guidance on operation. The Accu-Chek Aviva Connect builds upon this foundation, adding Bluetooth connectivity for seamless data transfer to smartphones. It’s intended for single-person use, ensuring hygiene and personalized monitoring. The system aims to provide comfort, convenience, and control to those living with diabetes, making self-management more accessible.
Intended Use of the Meter
The Accu-Chek Aviva meter, and its connected variant, the Accu-Chek Aviva Connect, are primarily intended for the quantitative measurement of glucose in fresh capillary whole blood. This means blood drawn from the fingertips, or other approved alternative testing sites. The core purpose is to aid individuals in monitoring the effectiveness of their glucose control, a crucial aspect of diabetes management.
These systems are designed for self-testing by a single person and are not intended for shared use due to hygiene and data privacy considerations. User manuals emphasize this single-patient application. The meter provides a numerical glucose reading, helping users and their healthcare providers make informed decisions about diet, exercise, and medication. It’s a tool for proactive health management, supported by readily available documentation.
Key Features and Benefits
The Accu-Chek Aviva system prioritizes comfort, convenience, and control for individuals managing diabetes. A key benefit is the availability of comprehensive user manuals, including quick start guides and advanced owners booklets, ensuring users can easily understand and operate the meter. The system’s design aims to simplify the testing process, making it less daunting for daily use.
The Accu-Chek Aviva Connect adds Bluetooth connectivity, enabling seamless data transfer to smartphones via a dedicated app. This feature provides enhanced data tracking and analysis capabilities. The system is designed for accurate glucose readings, aiding in effective diabetes management. Overall, the system empowers users to proactively manage their health with accessible information and convenient tools.

Kit Contents
The Accu-Chek Aviva kit includes a meter, test strips, a lancing device, lancets, and user manuals for comprehensive blood glucose monitoring at home.
Meter Overview
The Accu-Chek Aviva meter is a compact and user-friendly device designed for accurate blood glucose monitoring. It features a clear, easy-to-read display showing glucose readings, date, and time. The meter is specifically engineered to work with Accu-Chek Aviva test strips, providing reliable results for effective diabetes management.
Its intuitive design includes simple button operation for navigating menus and accessing stored readings; The meter’s memory function allows you to track your glucose levels over time, aiding in identifying trends and patterns. Furthermore, the Accu-Chek Aviva Connect version offers Bluetooth connectivity for seamless data transfer to a compatible smartphone, enhancing data analysis and sharing with healthcare professionals. Detailed instructions are available in the accompanying user manuals.
Test Strip Information
Accu-Chek Aviva test strips are crucial components of the blood glucose monitoring system, designed for use exclusively with the Accu-Chek Aviva meter. These strips contain chemicals that react with glucose in the blood sample, generating an electrical current measured by the meter to determine glucose concentration.
Proper storage of test strips is vital for accuracy; keep them in their original vial, tightly closed, in a cool, dry place. Do not use expired or damaged strips. Each strip is single-use only. The Aviva test strips are designed for fresh venous, arterial, neonatal, and capillary whole blood. Refer to your user manual for detailed instructions on proper strip handling and usage to ensure reliable results.
Lancing Device and Lancets
The Accu-Chek Aviva system includes a lancing device used to obtain a small blood sample, typically from a fingertip. This device utilizes single-use lancets to puncture the skin. Adjusting the depth setting on the lancing device is crucial for comfortable sampling; start with a shallower setting and increase if needed.
Always use a new, sterile lancet for each test to prevent infection and ensure accurate results. Dispose of used lancets safely in a sharps container, following local regulations. The lancing device is designed for single-person use and should not be shared. Refer to your user manual for detailed instructions on proper lancing device operation and lancet replacement.

Setting Up Your Meter
Accu-Chek Aviva meter setup involves battery insertion and precise date/time configuration, alongside memory function settings, ensuring accurate and personalized glucose monitoring.
Inserting the Battery
Accu-Chek Aviva meters typically require two AAA batteries for operation. To insert them, locate the battery compartment, usually on the back or side of the meter. Gently slide off the battery cover – avoid forcing it.

Observe the polarity markings (+ and -) inside the compartment and insert the batteries accordingly. Ensure the batteries are correctly aligned with these markings for proper functionality. Once the batteries are in place, carefully slide the battery cover back onto the meter until it clicks securely.
The meter should power on automatically, displaying a welcome screen or prompting you to set the date and time; If the meter doesn’t turn on, double-check the battery polarity and ensure the batteries are fresh and properly seated.
Setting the Date and Time
Accurate date and time settings are crucial for proper data logging and tracking of your blood glucose readings. Upon initial startup, or if the date/time is incorrect, the Accu-Chek Aviva meter will prompt you to set these.
Typically, you’ll navigate through the meter’s menu using the buttons on the device. Select the “Date” setting and use the buttons to adjust the month, day, and year. Repeat this process for the “Time” setting, adjusting the hour and minute.
Confirm each setting by pressing the designated button (often labeled “OK” or “Set”). Ensure you select the correct AM/PM designation. Once set, the meter will display the current date and time, confirming successful programming.
Setting Memory Function
The Accu-Chek Aviva meter boasts a memory function to store your blood glucose readings, allowing for trend analysis and review. The meter automatically saves results with the date and time. The memory capacity varies, typically storing hundreds of readings.
To access the memory, use the meter’s buttons to navigate to the “Memory” or “History” section within the menu. You can then scroll through your past results, often displaying average readings over specific periods (e.g., 7, 14, or 30 days).
Some models allow you to tag readings with mealtime or notes for better context. Regularly reviewing your stored data, alongside your healthcare provider, is vital for effective diabetes management.

Performing a Blood Glucose Test
Accu-Chek Aviva testing involves preparing the lancing device, applying a blood sample to a test strip, and then reading the glucose results on the meter.
Preparing the Lancing Device
Before beginning, ensure your hands are clean and dry. The Accu-Chek Aviva lancing device allows adjustable depth settings for personalized comfort. To prepare, remove the protective cap and insert a new, sterile lancet firmly into the device – do not attempt to reuse lancets.
Twist off the protective disc from the lancet. Then, adjust the depth setting dial on the lancing device; start with a lower setting and increase if needed to obtain an adequate blood sample. Replace the grey protective cap. Cock the lancing device by pressing the release button until you hear a click. Your lancing device is now prepared for obtaining a blood sample.
Remember to always use a fresh lancet for each test to minimize discomfort and ensure accurate results.
Applying a Blood Sample
After preparing the lancing device, firmly press it against the side of your fingertip – avoid the center for less discomfort. Press the release button to obtain a small drop of blood. Gently massage your finger towards the puncture site if needed to encourage blood flow, but avoid squeezing excessively.
Once a sufficient drop forms, carefully bring the Accu-Chek Aviva test strip’s sample area into contact with the blood drop. The strip will automatically draw in the required amount of blood. Do not smear the blood onto the strip; allow it to be absorbed. Ensure adequate lighting for accurate application.
Avoid touching the sample area of the test strip to maintain hygiene and prevent inaccurate readings.
Reading Your Results
Within seconds of applying the blood sample, your Accu-Chek Aviva meter will display your blood glucose result. The reading will appear clearly on the meter’s screen, typically in milligrams per deciliter (mg/dL). Ensure you are in a well-lit area to easily view the display.
The meter may also show symbols indicating pre- or post-meal status, or other relevant information. Familiarize yourself with these symbols by referring to your user manual. Note the date and time associated with the reading, as the meter automatically stores results with timestamps.
Record your results in a logbook or utilize the Accu-Chek Aviva Connect app for data tracking and analysis.

Understanding Your Results
Accu-Chek Aviva results require interpretation based on individual target ranges, considering factors like meals, exercise, and medication for effective diabetes control.
Target Range

Determining your personal target range is crucial for effective diabetes management with the Accu-Chek Aviva system. This range isn’t universal; it’s established in consultation with your healthcare provider, considering your age, overall health, diabetes type, and treatment plan.
Generally, a common target range before meals is 80-130 mg/dL, and less than 180 mg/dL two hours after starting a meal. However, these are guidelines, and your individual goals may differ.
Regularly discussing your results with your doctor allows for adjustments to your medication, diet, or exercise regimen to maintain optimal glucose control. Consistent monitoring with the Accu-Chek Aviva helps you stay within your personalized target range, promoting long-term health and minimizing complications.
High and Low Readings
Understanding high and low blood glucose readings is vital when using the Accu-Chek Aviva system. A reading consistently above your target range (hyperglycemia) may indicate a need to adjust medication, diet, or activity levels. Symptoms can include increased thirst, frequent urination, and blurred vision.
Conversely, a reading below your target range (hypoglycemia) requires immediate attention. Symptoms include shakiness, sweating, dizziness, and confusion. Follow your healthcare provider’s instructions for treating low blood sugar, often involving consuming fast-acting carbohydrates.
Record these occurrences and discuss them with your doctor to refine your diabetes management plan. The Accu-Chek Aviva helps identify trends, enabling proactive adjustments for better glucose control.
Factors Affecting Results
Several factors can influence the accuracy of your Accu-Chek Aviva readings. Dehydration, altitude, and temperature can all play a role. Ensure proper hydration and be aware of environmental conditions.
Incorrect test strip storage or expired strips will yield inaccurate results. Always store strips in a cool, dry place and check the expiration date before use. Additionally, improper testing technique – insufficient blood sample size or contamination – can affect readings.
Certain medications and medical conditions can also impact glucose levels. Discuss these with your healthcare provider; Maintaining consistent testing practices and noting any influencing factors will help ensure reliable monitoring.

Using the Accu-Chek Aviva Connect
Accu-Chek Aviva Connect systems enable Bluetooth pairing for seamless data transfer to a smartphone, offering app features for enhanced diabetes management.
Bluetooth Pairing
Pairing your Accu-Chek Aviva Connect meter with your smartphone is a crucial step to unlock its full potential. Ensure Bluetooth is enabled on your smartphone before beginning the process. Open the Accu-Chek Connect app and follow the on-screen instructions to initiate the pairing sequence.
The app will search for available devices, and your meter should appear in the list. Select your meter, and a pairing code may be displayed on both the meter and your phone. Confirm that the codes match and accept the pairing request.
Successful pairing allows for automatic data transfer of your blood glucose readings, eliminating the need for manual logging. This streamlined process enhances data tracking and provides valuable insights into your glucose control. Refer to the app’s help section for detailed troubleshooting steps if pairing fails.
Data Transfer to Smartphone
Once Bluetooth pairing is established, data transfer from your Accu-Chek Aviva Connect meter to your smartphone becomes automatic. Each time you perform a blood glucose test, the reading is wirelessly transmitted to the Accu-Chek Connect app.

This seamless transfer eliminates manual logging, ensuring accurate and consistent record-keeping. The app displays your readings in a clear and organized format, allowing you to easily review trends and patterns. Data is securely stored within the app, providing a comprehensive history of your glucose levels.
You can also export this data to share with your healthcare provider, facilitating informed discussions about your diabetes management plan. Ensure your smartphone remains within Bluetooth range of the meter during and after testing for successful data synchronization.
App Features and Benefits
The Accu-Chek Connect app, paired with your Aviva Connect meter, offers a wealth of features designed to empower your diabetes management. Beyond simple data logging, the app provides personalized insights into your glucose patterns, helping you understand how diet, exercise, and medication affect your levels.
You can set reminders for testing, ensuring consistent monitoring. The app also allows you to track your insulin dosages and carbohydrate intake, creating a holistic view of your diabetes care. Trend arrows visually indicate whether your glucose is rising, falling, or stable, providing immediate feedback.
Furthermore, the app facilitates easy sharing of data with your healthcare team, promoting collaborative care and optimized treatment plans.

Troubleshooting
Encountering issues? Refer to the Accu-Chek Aviva user manual for error message solutions, common fixes, and contact information for dedicated customer support assistance.
Error Messages and Solutions
The Accu-Chek Aviva meter displays error codes to indicate potential problems during testing. Understanding these messages is crucial for accurate results. For example, an “E-1” error often signifies a communication issue between the test strip and the meter; ensure proper strip insertion.
“E-2” typically indicates an issue with the test strip itself – it may be damaged, expired, or improperly stored. Always use unexpired strips and store them correctly. If you receive an “E-7” message, it suggests a potential issue with the meter’s internal components, requiring contact with customer support.
Consult your Accu-Chek Aviva user manual for a comprehensive list of error codes and their corresponding solutions. Retesting with a new strip is often the first step in resolving these issues.
Common Issues and Fixes
Accu-Chek Aviva users sometimes encounter difficulties obtaining sufficient blood samples. Gently warming hands or lightly massaging the fingertip can improve blood flow. Another frequent issue is inconsistent results; ensure test strips are stored in a cool, dry place and the container is tightly sealed.
If the meter doesn’t turn on, verify the battery is correctly installed and has sufficient charge. Occasionally, the meter may display inaccurate readings due to contamination; clean the meter with a soft, dry cloth.
Always double-check the expiration date on test strips. Refer to your Accu-Chek Aviva user manual for detailed troubleshooting steps and remember not to share the device with others.
Contacting Customer Support
If you’ve consulted your Accu-Chek Aviva user manual and are still experiencing issues, Roche Diabetes Care offers comprehensive customer support. You can access their online resources, including FAQs and troubleshooting guides, through their official website.
For direct assistance, you can reach their customer service team via phone. Their representatives are available to address your concerns and provide personalized support. Online chat support is also frequently available for quick resolutions.
Ensure you have your meter’s model number and any error codes displayed when contacting support. Roche also provides resources for diabetes education and management, furthering support beyond technical assistance.